MEHITS Witness Test

Turn HVAC design into an exact science and make your heating and cooling system operation completely transparent, predictable and reliable

MEHITS Witness Test is an additional service for consultants and customers, to enable them to know in advance how the unit will operate once installed, verifying design assumptions, performance and noise emission levels, as well as operation in exceptional conditions. Witness Test adds up to MEHITS comprehensive, certified standard testing procedures applied to all units, as a possibility to study in advance how the unit integrates once installed, eliminating any risk at start up and during operation.

Know beforehand how the unit will operate once installed

Verify in advance performances, noise emissions, design assumptions, operation under severe conditions

Eliminate any risk at start up


Thanks to the state-of-the-art testing rooms, with the support of highly qualified personnel, the consultant and the client can run the unit in any condition, checking:

Performance, both at full and partial loads

Low temperature performance and operating conditions

Sound emissions

Unit and system operation under severe conditions

Failure tests

Witness Test Facilities

MEHITS has important manufacturing locations for witness tests in Belluno, Bassano and Pavia focused on testing chillers, reversible chillers units and high precision air conditioners. Carried out in modern, sophisticated laboratiories, MEHITS witness tests combine the advantages of empirical evidence with the guarantee of certified performances, delivering consultants and clients with the most reliable certificates of performance in the market.

Witness Test Overview

Witness test service can be ordered as an additional service when ordering a unit.

Hydronic systems

Performance Witness Test

Following operating modes - multiple choice is possible – are measured:

  • Cooling only, air and water source
  • Heat pump air source and water source, water or gas side reversible
  • Heat Recovery

All parameters are read and measured by the acquisition system in stable conditions. Tests are carried out in accordance with EN14511:2011.

Performance parameters read and measured in stable conditions. The functional and performance parameters read and displayed by the acquisition system are the following:

  • R-phase current (A)
  • S-phase current (A)
  • T-phase current (A)
  • Line voltage (V)
  • Input power (kW)
  • Power factor
  • Evaporator/condenser water inlet temperature (°C)
  •  Evaporator/condenser water outlet temperature (°C)
  •  Evaporator/condenser water flow (m3/h)
  • Evaporator/condenser capacity (kW)
  • Total EER (compressors and fans) at 100% or at partial pressure loads
  • Test room air temperature (°C)
  •  Percentage of unit/compressors capacity in stable conditions (N° Load, N° Comp)

All performance parameters are read and measured by the acquisition system ONLY in stable conditions. The values measured during transient times ARE NOT RELEVANT. A test report summarizing the test results shall only be released in stable conditions.


Acoustic Witness Test

Climaveneta noise tests are performed as per the intensimetric method.

Noise data are recorded in stable conditions only.

The acoustic parameters read are the following:
- Sound level measured as per ISO 3744*

*Sometimes, being forced to take advantage of the hours with lower background noise, the outdoor temperature may be less than 20°C.

At the end of the test, which is performed only in stable conditions, it is issued a summarizing document including the measured acoustic performances.


Low outdoor air temperature operation

Chiller operation and start-up is tested in a dedicated structure cooled with liquid azoto, creating outdoor air temperature down to - 25°C.


Special Witness Test requests

Special testing requests exceeding normal testing rooms operating limits or not listed in the technical document can be required as special witness test, and are evaluated on a case by case basis.


Precision conditioners

Performance Witness Test

All parameters are read and measured by the acquisition system in stable conditions. Performance parameters read and measured by the acquisition system in stable conditions.

  • Ambient air temperature [°C]
  • Ambient air relative humidity [%]
  • ESP External static pressure [Pa]
  • Water inlet temperature [°C]
  • Water outlet temperature [°C]
  • Water flow [m3/h]
  • Water pressure drop [kPa]
  • Outdoor air temperature [°C]
  • Total cooling capacity [kW]
  • Sensible cooling capacity [kW]
  • R-phase current [A]
  • S-phase current [A]
  • T-phase current [A]
  • Line voltage [V]
  • Power factor
  • Input power [kW]
  • EER

Acoustic Witness Test

Climaveneta offers acoustic witness testing according to ISO3744. Acoustic parameters read and measured using in-house instruments.

Sound power level (SWL) is calculated starting from the measure of the sound pressure level (SPL) which is measured in accordance with ISO 3744.


Special Witness Test requests

Special testing requests exceeding normal testing rooms operating limits or not listed in the technical document can be required as special witness test, and are evaluated on a case by case basis.

Download Witness Test brochure
Witness Test

Witness test Brochures

Witness Test

27/02/2018

A world of services around you

The quality of a solution, the excellence of performance and the satisfaction of the end user also depend on how the company assists the customer after commissioning of the system.

Mitsubishi Electric's mission is to guarantee its customers the benefit of superior comfort, to safeguard energy consumption and to maintain the value of its investments unchanged, operating in full compliance with current regulations.

From the stage of design to the dispatch of each unit, and during the entire system life cycle, Mitusbishi Electric Hydronics & IT Cooling Systems supports the customer with services aimed at satisfying all specific needs, training the technical staff, ensuring their continuous updating and constantly improving their level of preparation.

Mehits Academy

The training courses for our partners.

Keeping up with technological innovation?
Turn to MEHITS experts to receive high-level technical training. Taught by the most experienced and knowledgeable experts, MEHITS presents a new offer of technical courses dedicated to their partners and distributors.

Comprehensive and high-level courses to allow HVAC engineers to keep up with the ever-changing technological choices and to address a variety of topics in the world of air conditioning.